Lighting Optics Explained: Beam Angle, Lux and Glare

照明光学の解説:ビーム角、ルクス、グレア

A beam angle is measured where intensity falls to 50% of peak, not at the edge of visible light. That convention alone explains why two 36° downlights can cover floors a metre apart in diameter. Optics decide three things at once: the spot size on the floor, the lux inside that spot, and how bright the source looks from a seated position.

Choose the angle well and a 12 W fitting does the work of a 20 W one. Choose it badly and you compensate with wattage, which raises glare. This page covers the vocabulary, the arithmetic, the application choices and the glare limits, so a lighting schedule can be checked before samples arrive.

1. Beam angle vs field angle

Manufacturers publish beam angle at the point where luminous intensity drops to 50% of its peak value. Field angle is measured at 10% of peak. Both numbers come from the same candela distribution, and both describe the same cone from different heights on the curve.

Conceptual beam angle and field angle diagram showing relative intensity boundaries

The practical ratio is close to 2:1. A luminaire quoted at 36° beam usually carries a field angle of 60° to 70°. The beam angle is the part of the light you can point at something. The field angle is the part that spills past it.

Two fixtures with the same beam angle can still behave differently. A reflector with a hard cut-off puts most of its energy inside the 50% cone; one with a soft, gradual fall-off puts 35% of its flux outside it. The first gives a crisp pool of light on a table. The second washes the surrounding ceiling and wall, which may be desirable in a lobby and unwanted in a restaurant where the tables should read as separate.

Ask for both numbers when you request samples. A datasheet that lists only beam angle is describing half the fixture.

The angle can be measured in a dark room without a goniophotometer. Put a lux meter on the floor directly under the fitting, note the reading, then move the meter outward until it reads half. The ratio between that distance and the mounting height gives tan(θ/2), so a reading that halves at 0.62 m under a 2.7 m ceiling means 24°. Doing it twice on a sample catches the mismatch between a datasheet and the actual optic, which is the usual cause of a mock-up that looks wrong.

Beam angleMultiplierSpot diameter at 2.7 mSpot diameter at 3 mSpot diameter at 4 m
15°0.2630.71 m0.79 m1.05 m
24°0.4251.15 m1.28 m1.70 m
36°0.6501.75 m1.95 m2.60 m
60°1.1553.12 m3.46 m4.62 m

Diameter follows D ≈ 2 × H × tan(θ/2), where H is the distance from the lens to the surface and θ is the beam angle. The multiplier column is that formula with the angle already resolved, so the table can be used on site without a calculator. The number is the 50% diameter, which is why a 36° downlight at 3 m lights a 1.95 m circle and still leaves a visible glow beyond 3 m.

2. Candela, lux and the inverse-square law

Three units do all the work. Candela (cd) is intensity in a direction — how hard the fixture throws. Lumen (lm) is total flux out of the fixture. Lux (lx) is flux landing on a square metre, so 1 lx = 1 lm/m².

The conversion that matters on site is E = I / d²: illuminance equals intensity divided by distance squared. Double the mounting height and you get a quarter of the lux. That is geometric, not a quality issue, and no driver setting changes it.

A 1,500 lm downlight at 24° concentrates its output into a narrow cone. Peak intensity works out near 12,500 cd, so at 3 m the on-axis illuminance is roughly 12,500 / 9 = 1,390 lx. The same 1,500 lm spread over 60° gives about 1,090 cd and roughly 120 lx at the same height. Same wattage, same lumen count, a factor of eleven in the result.

This is where lumen-only comparisons fail. A 2,000 lm 60° downlight and a 1,200 lm 24° accent are not rivals; they solve different problems. If a schedule lists wattage and lumens but not beam angle, the numbers cannot be converted into lux at the ceiling height you are building.

The inverse-square law only holds on axis, measured perpendicular to the surface. Off-axis, illuminance falls further by the cosine of the angle of incidence. At 45° from nadir the surface receives 71% of the on-axis value before you account for the beam’s own fall-off, so the outer part of a pool of light dims faster than distance alone suggests.

FixturePeak intensity2.7 m3 m4 m6 m
1,500 lm, 24°≈ 12,500 cd1,715 lx1,390 lx780 lx347 lx
1,500 lm, 36°≈ 5,600 cd768 lx622 lx350 lx156 lx
800 lm, 60°≈ 1,090 cd150 lx121 lx68 lx30 lx

Peak intensity here is estimated at 1.15× the average over the beam solid angle. Real values come from the photometric file, and the estimate is only for sanity-checking a datasheet that quotes lumens and nothing else.

3. Choosing beam angles by application

Ceiling height sets the floor, task geometry sets the angle. Work from the surface you need to light back to the fixture, never the other way round. A 4.5 m lobby with 24° fittings needs them spaced about 1.7 m apart to keep pools from separating; the same fittings at 15° would leave dark bands between them.

  • 15°–20°: accent on a single object, art, a plant, a table centre. Spot diameter stays under 1.1 m at 4 m, so aim matters more than spacing.
  • 24°: the default for retail display, reception desks and wall washing on tall walls. Tight enough to build contrast, wide enough to survive a small aiming error.
  • 36°: general downlighting in guestrooms, restaurants and lounges. At 3 m it covers 1.95 m, which suits tables spaced 1.8–2.2 m apart.
  • 60°: circulation, bathrooms, back-of-house. Wide pools, lower lux on axis, fewer fittings for even coverage.
  • Asymmetric: linear wall washers and shelf lights, where the beam is 10° × 60° and throws sideways rather than down.

Height changes the answer more than the application does. A 36° fitting at 2.7 m is a comfortable general light; at 6 m it is a soft glow that cannot meet 200 lx on a lobby floor without help. Above 4 m, either narrow the angle and raise the wattage, or accept that ambient light comes from a second layer.

空間Typical angleMounting heightResult on the surface
Hotel lobby, accent15°–24°4–6 m0.8–2.6 m pools, 500–1,400 lx on axis
Guestroom general36°–60°2.6–2.8 m1.6–3.2 m pools, 100–200 lx
Restaurant table24°–36°2.4–3 m1.0–2.0 m pools, table reads as its own zone
Retail display15°–24°2.8–3.5 m750–1,000 lx, 3× ambient
廊下60°2.4–2.7 m2.8–3.1 m pools, even 100 lx
Office task60°–90°2.7–3 mOverlapping pools, 500 lx maintained

4. Glare: UGR, luminance and shielding

Glare is not brightness. It is brightness relative to what surrounds it. A 3,000 cd/m² downlight against a 200 cd/m² ceiling is uncomfortable; the same fixture against a bright window is invisible. That ratio, plus the angle between the source and the viewer’s line of sight, is what UGR models.

Sightline comparison of an exposed light source and a shielded luminaire in a seating area

Unified Glare Rating runs on a 10–28 scale. EN 12464-1 sets UGR ≤ 19 for offices and writing tasks, ≤ 22 for dining, and ≤ 25 for corridors and back-of-house. Reading in bed is stricter still; treat UGR ≤ 16 as the target when the source can enter a guest’s field of view at 1 m.

Shielding does most of the work. A shielding angle of 30° or more — the angle between the horizontal and the line from the lamp to the baffle edge — keeps the LED out of sight for anyone standing or seated below. A baffle 40 mm deep typically buys 3–5 UGR points at the same output. A honeycomb or cross-louvre accessory buys another 2–3, at the cost of 8–12% of the lumens.

The other variable is where the eye sits. UGR weights each source by a position index that rises steeply as the source moves toward the centre of the field of view. A 1,000 cd/m² fitting 45° above the sightline contributes far less than the same fitting 10° above it, which is why recessing or a snoot beats a lower-output lamp in a guestroom.

The counter-intuitive part: narrow beams glare more. A 15° accent at 500 cd has a small bright source, and small bright sources are exactly what the eye reacts to. That is why accent fittings in guestrooms need deep recessing or a snoot even though their total output is modest. Full treatment of the calculation, luminance limits and placement errors is in the UGR and glare guide.

Luminance is the number to check, not lux. Above roughly 1,000 cd/m² at normal viewing angles, a source in the field of view starts to read as a point of discomfort in a dim room. That threshold is why the same fitting works in a 300 lx office and fails in a 50 lx lounge.

5. Reading IES/LDT photometric files

Two formats cover almost every project: IES LM-63 (.ies) and Eulumdat (.ldt). Both hold a candela table sampled over vertical and horizontal angles, plus the luminaire’s total flux and wattage. Neither is a rendering; both are measurements of one physical sample.

What to check, in order:

  • Total flux in the file matches the lumen figure on the datasheet. A 2,000 lm claim with a 1,780 lm file is common, and the file is the honest one.
  • C-plane count. Rotational symmetry needs at least two planes; an asymmetric wall washer needs 0°/90° or more, or the file cannot describe it.
  • Vertical angle step. A 5° step rounds off a 15° beam badly. 2.5° or finer is normal for narrow optics.
  • Absolute vs relative photometry. Relative files are scaled by a factor; if the software ignores it, every lux value is off by that factor.
  • Spacing criterion, if present, gives the manufacturer’s own mounting-height multiple for even coverage. It is a useful cross-check on the spacing you planned.

DIALux and Relux both read either format, and both will happily calculate a room from a file that does not match the delivered product. The check is administrative, not technical: compare the file’s total flux and wattage with the purchase order, then check the revision date. Facilities teams that keep a copy of the submitted file with the project handover avoid the argument two years later when a replacement is ordered.

Optical efficiency is the share of LED flux that leaves the fitting. It ranges from about 55% in a heavily baffled accent to over 85% in a polished reflector, and it is not visible in a lumen figure taken at the LED. Two fittings with the same chip and different optics can differ by 30% in delivered lumens, which is one more reason to quote the file rather than the LED datasheet.

A file is valid only for the exact LED, bin and driver combination that was tested. Swap the driver for a different output current and the candela table no longer applies. For project submissions, ask for the LM-79 test report alongside the file, and check that the report’s date is after the last LED change. Files older than the current BOM are the most common reason a mock-up does not match the calculation.

Wall washing and grazing need asymmetric distributions that no round-beam table can describe. Those optics are covered separately in wall washing versus wall grazing, including the offsets and spacing that keep a wall even.

6. Optics checklist for specifiers

Run this list against any submitted schedule or sample. Each line catches a failure that shows up on site, not in the render.

  • Beam angle and field angle quoted, both from a current photometric file.
  • Spot diameter calculated at the actual mounting height, not the catalogue’s 1 m reference.
  • Lux on the task surface checked after applying the maintenance factor (0.8 is a fair default for a hotel).
  • Spacing between fittings no more than 1.2× the spot diameter, or pools will separate.
  • UGR ≤ 19 for task areas, ≤ 22 for dining, and shielding angle ≥ 30° wherever the source is visible.
  • Source luminance under 1,000 cd/m² at the angles a guest will actually look from.
  • Beam angle consistent across a run. Mixing 24° and 36° in one ceiling line is visible from the door.
  • Photometric file dated after the last LED or driver change, with the LM-79 report attached.
  • Asymmetric optics specified for wall washing, with the 10° × 60° orientation marked on the drawing.
  • Colour temperature within 300 K across the visible field, so no fixture reads as a different white.

Most of these are cheap to fix on paper and expensive to fix after the ceiling is closed. The arithmetic in sections 1 and 2 takes about ten minutes per room type and settles the arguments before the mock-up.

Frequently asked questions

Is beam angle the same as field angle?

No. Beam angle is where intensity falls to 50% of peak; field angle is where it falls to 10%. The field angle is always wider, typically 1.7 to 2 times the beam angle. Use beam angle for spot size and lux calculations, and field angle to judge spill onto walls and ceilings.

Does a narrower beam angle give more lux?

Yes, at the same lumen output. Narrowing from 60° to 24° concentrates the same flux into about one sixth of the solid angle, so on-axis intensity rises roughly sixfold. That is why a 12 W accent can out-light a 25 W wide-beam downlight directly under it, and why the accent glares more.

What beam angle suits a 3 m hotel corridor?

Use 60° for the general layer at 2.4–2.7 m, giving 2.8–3.1 m pools that overlap into an even 100 lx. If you want scallops on the wall instead, use 24° wall washers at 0.6–1.0 m from the wall with spacing no wider than the offset.

What UGR is acceptable in a guestroom?

EN 12464-1 does not set a guestroom figure. In practice, keep any source in the sightline at UGR ≤ 16 to 19, and keep bedhead reading lights below 1,000 cd/m² at the pillow. A 300 lx reading task with a deep-set 24° fitting works; an exposed 15° spot at the same output does not.

Can I compare lux figures between two brands’ datasheets?

Only if both use the same distance, the same beam angle and the same reference surface. Many datasheets quote lux at 1 m, which flatters narrow optics. Recalculate from candela and your real mounting height before comparing, or the comparison is meaningless.

Next step

If you are checking a schedule against these rules, the fastest route is the photometric file itself. Qilux supplies IES and LDT files, LM-79 reports and lux calculations for the exact LED and driver combination quoted, per room type and mounting height. Send the ceiling heights and the surfaces you need to light through our engineering capabilities page, and the files come back with the beam angles already resolved into spot diameters and maintained lux.

For fixture families by application, start with the downlight range または architectural project lighting. If the task is sizing rather than optics, the beam angle calculator walkthrough takes the same formula and applies it room by room.