Wall-mounted lighting is the layer a ceiling fitting cannot do: it puts light where a person actually is, at reading height, at a mirror, along a corridor handrail, on a staircase. It is also the layer that takes the most abuse in a commercial building, because it is within reach of guests, cleaning staff and luggage trolleys.

What this range covers

Bedside and reading lights, technical wall lights for corridors and stairwells, and surface-mounted fixtures for commercial interiors. The common thread is mounting: everything here fixes to a wall and directs light along or across a surface rather than down from the ceiling. Decorative pendants and chandeliers sit under Decorative Lighting; mirror and bathroom-specific fixtures sit under Mirror & Bathroom Lighting.

Corridor and staircase lighting

A hotel corridor runs at around 100 lux at floor level with a uniformity that does not leave dead patches outside room doors. Wall lights work better than downlights here because they light the door face and the signage, not just the carpet, and because a wall-mounted fixture at 1.8 m to 2.0 m above the finished floor is out of the cleaning trolley's path.

On a staircase the fixture height is set by the handrail, not by symmetry: 1.8 m to 2.0 m above the pitch line keeps the source below eye height on the flight and above head height on the landing. Anything lower becomes a glare source for anyone walking up.

Reading and bedside fixtures

A bedside light is judged by whether it disturbs the person next to you. The head should be adjustable, the beam narrow enough to reach a book and not the pillow, and the switching independent of the room circuit. 0.9 m to 1.2 m above the mattress is the working range, with the head aimed back toward the reader rather than straight out into the room.

Colour temperature in a guestroom stays at 2700 K to 3000 K, with CRI 90 and above so that skin tones and printed material read correctly. Dimming down to 10 percent or lower is what makes a bedside light usable at night.

Technical wall lights for commercial interiors

Corridors, back of house, plant rooms, service areas and stair cores need a fixture that survives being hit. Look for a die-cast or extruded body rather than folded steel, a gasketed diffuser on exterior or wet areas, and an IP rating that matches the cleaning regime rather than the weather. IP44 is the working minimum for anything within reach of a hose; IP65 where a fitting faces a jet.

Materials and finishes

Solid brass and powder-coated aluminium both age predictably; plated finishes do not. In a hotel that refurbishes on a seven-year cycle the finish matters more than the LED, because the electronics can be replaced and the housing cannot be re-plated in situ.

Specification support

Send the wall construction, the mounting height and the target illuminance. We return a schedule with reference numbers, IP ratings and finish options, and where the wall cannot take a back box we propose a surface or track-mounted alternative from the same family.