Qilux Lighting

PRODUCTS / Bedroom Lighting

Bedroom Lighting

132 fixtures in this family. Filter by type, space or material, then bring the references into a project enquiry.

Qilux Downlight 175 mm — 8601-R-Q-175-H Downlights & Spotlights
Downlights & Spotlights

Downlight 175 mm — 8601-R-Q-175-H

View fixture ↗
Qilux Downlight 75 mm — 8602-R003-Q-75-B6 Downlights & Spotlights
Downlights & Spotlights

Downlight 75 mm — 8602-R003-Q-75-B6

View fixture ↗
Qilux Downlight 75 mm — 8602-R003-Q-75-B5 Downlights & Spotlights
Downlights & Spotlights

Downlight 75 mm — 8602-R003-Q-75-B5

View fixture ↗
Qilux Downlight 75 mm — 8602-R003-Q-75-B4 Downlights & Spotlights
Downlights & Spotlights

Downlight 75 mm — 8602-R003-Q-75-B4

View fixture ↗
Qilux Track Spotlight 120×50 — 8601-SE-T120050-H1 Track Lighting Systems
Track Lighting Systems

Track Spotlight 120×50 — 8601-SE-T120050-H1

View fixture ↗
Qilux Track Spotlight 120×50 — 8601-SE-T120050-H Track Lighting Systems
Track Lighting Systems

Track Spotlight 120×50 — 8601-SE-T120050-H

View fixture ↗
Qilux Track Spotlight 95×47 — 8601-SE-T095047-H1 Track Lighting Systems
Track Lighting Systems

Track Spotlight 95×47 — 8601-SE-T095047-H1

View fixture ↗
Qilux Track Spotlight 95×47 — 8601-SE-T095047-H Track Lighting Systems
Track Lighting Systems

Track Spotlight 95×47 — 8601-SE-T095047-H

View fixture ↗
Qilux Track Spotlight 72×40 — 8601-SE-T072040-A-H1 Track Lighting Systems
Track Lighting Systems

Track Spotlight 72×40 — 8601-SE-T072040-A-H1

View fixture ↗
Qilux Track Spotlight 72×40 — 8601-SE-T072040-A-H Track Lighting Systems
Track Lighting Systems

Track Spotlight 72×40 — 8601-SE-T072040-A-H

View fixture ↗
Qilux Downlight 200 mm — 8601-SE-Q-200-H1 Downlights & Spotlights
Downlights & Spotlights

Downlight 200 mm — 8601-SE-Q-200-H1

View fixture ↗
Qilux Downlight 200 mm — 8601-SE-Q-200-H Downlights & Spotlights
Downlights & Spotlights

Downlight 200 mm — 8601-SE-Q-200-H

View fixture ↗
Qilux Downlight 175 mm — 8601-SE-Q-175-H1 Downlights & Spotlights
Downlights & Spotlights

Downlight 175 mm — 8601-SE-Q-175-H1

View fixture ↗
Qilux Downlight 175 mm — 8601-SE-Q-175-H Downlights & Spotlights
Downlights & Spotlights

Downlight 175 mm — 8601-SE-Q-175-H

View fixture ↗
Qilux Downlight 150 mm — 8601-SE-Q-150-H1 Downlights & Spotlights
Downlights & Spotlights

Downlight 150 mm — 8601-SE-Q-150-H1

View fixture ↗
Qilux Downlight 150 mm — 8601-SE-Q-150-H Downlights & Spotlights
Downlights & Spotlights

Downlight 150 mm — 8601-SE-Q-150-H

View fixture ↗
Qilux Downlight 125 mm — 8601-SE-Q-125-H1 Downlights & Spotlights
Downlights & Spotlights

Downlight 125 mm — 8601-SE-Q-125-H1

View fixture ↗
Qilux Downlight 125 mm — 8601-SE-Q-125-H Downlights & Spotlights
Downlights & Spotlights

Downlight 125 mm — 8601-SE-Q-125-H

View fixture ↗
Qilux Downlight 100 mm — 8601-SE-Q-100-H1 Downlights & Spotlights
Downlights & Spotlights

Downlight 100 mm — 8601-SE-Q-100-H1

View fixture ↗
Qilux Downlight 100 mm — 8601-SE-Q-100-H Downlights & Spotlights
Downlights & Spotlights

Downlight 100 mm — 8601-SE-Q-100-H

View fixture ↗
Qilux Downlight 75 mm — 8601-SE-Q-75-H1 Downlights & Spotlights
Downlights & Spotlights

Downlight 75 mm — 8601-SE-Q-75-H1

View fixture ↗
Qilux Downlight 75 mm — 8601-SE-Q-75-H Downlights & Spotlights
Downlights & Spotlights

Downlight 75 mm — 8601-SE-Q-75-H

View fixture ↗
Qilux Downlight 185 mm — 8601-SE-M1-185-H1 Downlights & Spotlights
Downlights & Spotlights

Downlight 185 mm — 8601-SE-M1-185-H1

View fixture ↗
Qilux Downlight 185 mm — 8601-SE-M1-185-H Downlights & Spotlights
Downlights & Spotlights

Downlight 185 mm — 8601-SE-M1-185-H

View fixture ↗
1 2 3 … 6

Need a different size or finish?

Any model can be adapted for a project brief — dimensions, materials, finishes and light colour.

Explore Custom Lighting ↗

A bedroom needs three separate layers of light, and almost every badly lit bedroom is missing one of them. Ambient light fills the room, task light serves reading and dressing, accent light gives the room depth after dark. A single ceiling fitting does none of these well.

The three lighting layers in a bedroom

Ambient light comes from recessed downlights or a central diffused fitting at 2700 K to 3000 K. We size it at roughly 100 to 150 lux at floor level for a domestic bedroom and 150 to 200 lux for a hotel guestroom, where the room also has to be cleaned and inspected.

Task light is the layer most often skipped. Reading light should sit 600 to 750 mm above the mattress top on each side, aimed at the page rather than the pillow. Downlights placed directly above the bed are the wrong answer: they light the top of the head and nothing else. Accent light is what makes a bedroom feel finished, whether that is a wall light grazing a textured wall, a floor lamp in the corner or a table lamp on a sideboard.

Bedside wall lights vs table lamps

Bedside wall lights free up the bedside table and put the light source at the right height without a cable. They suit hotel rooms where housekeeping needs a clear surface and where guests expect a fixed switch beside the bed. Table lamps suit residential bedrooms and boutique hotels where the lamp itself is part of the design.

The trade-off is flexibility. A wall light is fixed at installation; a table lamp can be moved and swapped. For a hotel on a five-year refit cycle we usually specify wall lights, because they survive better and cannot walk away.

Reading light placement and aiming

A reading light wants to be within 300 mm of the reader's shoulder, on the outside of the bed, and adjustable. Fixed downlights over a bed fail because they cannot be aimed. Adjustable wall lights or a swing-arm fitting solve this without taking table space.

Glare control matters here. The source should be shielded so a guest lying down does not see the bare lamp.

Dimming and warm colour temperature

Bedroom lighting should dim to at least 10 percent. 2700 K is the safe choice for guestrooms; 3000 K works in more contemporary interiors but reads colder at night. Mixing the two within one room is the most common mistake we see in refurbishments.

Hotel guestroom application

A standard guestroom uses four lighting circuits: entrance, bathroom, bedside and general ambient. We supply the wall and reading layer as a matched set so finish, colour temperature and dimming curve stay consistent across every room in the building.

Related reading