Qilux Lighting

EU Ecodesign and UKCA: What Hotel Projects Must Check

Ecodiseño de la UE y UKCA: qué deben comprobar los proyectos hoteleros

A luminaire can be perfectly built, beautifully finished and still be illegal to place on the market, because the rules that decide this are about documents rather than light output. Since September 2021 the EU has applied ecodesign limits to light sources, the UK has run its own marking regime in parallel, and both now expect the manufacturer to hold test evidence rather than a certificate bought from a website. This guide sets out what each regulation actually requires, where CE and UKCA differ, which declarations a hotel project should collect, and the specific documents that hold up a handover when they are missing.

1. ERP 2019/2020 in one page

Regulation (EU) 2019/2020 sets ecodesign requirements for light sources and separate control gear. It does not regulate luminaires as such, which is the source of most confusion on a project, because a luminaire is caught indirectly.

The scope works like this. A light source — a lamp, a module, an LED strip — must meet the requirements to be placed on the EU market. A luminaire that contains a light source must contain one that complies, and must allow that source to be replaced without destructive disassembly, unless the manufacturer declares the luminaire as a “containing product” that cannot be opened. A luminaire with an integrated, non-replaceable LED module is assessed as though the module were the light source, and the whole fitting inherits the assessment.

Four requirements matter to a specifier. Minimum efficacy, which rises in stages and rules out most low-output decorative sources. Colour rendering at Ra ≥ 80 for the source to claim compliance. Standby power limits for any product with a standby mode. And flicker metrics, dealt with in section 4.

There are exemptions, and they are narrow: light sources for emergency lighting, for explosive atmospheres, for radiological and nuclear installations, for military and civil-defence use, and for transport vehicles. Decorative “mood” lighting is not exempt, which is why the low-efficacy filament lamps that filled hotel corridors in 2019 have largely gone. If a specification written in 2019 still names one, the product may no longer be placeable, and the substitution will have a different wattage and a different lumen output. Write a substitution clause before tender rather than after.

2. CE marking and the UKCA transition

CE marking on a luminaire is a self-declaration, but “self” means the manufacturer holds the evidence, not that no evidence is needed. For a typical decorative fitting the applicable directives are Low Voltage 2014/35/EU for mains-voltage products, EMC 2014/30/EU, RoHS, and ecodesign where a light source or control gear is supplied.

Market review diagram distinguishing Great Britain, Northern Ireland and European Union marking routes

The technical file behind the mark has to contain the risk assessment, the standards applied, the test reports, the label artwork and the Declaration of Conformity. It must be kept for ten years after the last unit is placed on the market, and it is the file an authority asks for if a fitting is questioned on site.

UKCA is the GB equivalent, introduced in 2021. The position has moved twice since, and the practical summary for a hotel project is: for electrical safety and EMC, GB has continued to recognise CE, with an indefinite extension announced in 2024. For the GB RoHS and ecodesign regimes, CE recognition was not extended in the same way, so a product needs UKCA or the applicable UK conformity route for those aspects. A dual-marked product with both an EU and a GB Declaration of Conformity is the low-risk answer, and it is what a UK main contractor will ask for.

Two practical consequences. First, ask for the GB declaration separately; suppliers often send the EU one and assume it covers both. Second, check the position at the date of the order rather than relying on this page, because the transition has been extended more than once and the exemptions have changed each time.

3. RoHS and REACH for finishes

RoHS 2, Directive 2011/65/EU as amended by (EU) 2015/863, restricts ten substances in electrical equipment: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers, and four phthalates. Limits are 0.1% by weight in homogeneous material, except cadmium at 0.01%.

“Homogeneous material” is the phrase that decides most arguments. A brass body, a lacquer coating, a solder joint and a crystal drop are four separate materials, and each is assessed on its own. This is why a fitting can pass on the electronics and fail on the finish, and why the finish supplier is part of the compliance chain rather than outside it.

Brass is the usual point of tension. Many free-machining brasses contain 1–3% lead, which is far above the 0.1% limit, and they rely on a RoHS exemption for lead as an alloying element in copper alloys up to 4% by weight. The exemption is legitimate, but it must be claimed by number in the declaration. A supplier who says “our brass is RoHS compliant” without naming the exemption has either used a lead-free alloy or has not checked.

REACH is separate and catches the finishes RoHS misses. Substances of Very High Concern above 0.1% by weight in an article require communication down the supply chain and to consumers on request, and since 2021 an EU article containing an SVHC above that threshold must also be notified to the SCIP database. Lead crystal is the classic case: at PbO ≥ 24% the lead content is orders of magnitude above 0.1%, so a declaration is unavoidable. The candidate list is updated twice a year, so ask for a declaration dated within the last six months rather than one from 2019.

4. Flicker and efficacy limits

Flicker moved from a comfort issue to a legal limit when 2019/2020 took effect, and the test methods in 2021/341 define how it is measured. Two metrics apply to the light source: SVM, the stroboscopic effect visibility measure, at or below 0.4, and Pst LM, short-term flicker severity, at or below 1.0.

These sit alongside the older IEEE 1789-2015 guidance, which is still the reference most lighting designers use for modulation depth: below 90 Hz the depth should stay under 8%, between 90 Hz and 1,250 Hz the limit relaxes linearly, and above 1,250 Hz there is effectively no restriction. A driver that dims by low-frequency PWM will fail the first test and pass nothing else.

ParámetroLimitReferenceWhere it is checked
SVM (stroboscopic effect)≤ 0.4EU 2019/2020Light source, at full and dimmed output
Pst LM (short-term flicker)≤ 1.0EU 2019/2020Light source, 10-minute measurement
Modulation depth below 90 Hz< 8%IEEE 1789-2015Driver output waveform
Colour rendering for complianceRa ≥ 80EU 2019/2020Light source datasheet
Standby power≤ 0.5 WEU 2019/2020Control gear in standby
Networked standby≤ 2 WEU 2019/2020Connected light sources

Flicker gets worse as dimming deepens, so the measurement point matters. A fixture that passes at 100% and fails at 1% will still be installed at 1% in a hotel guestroom at midnight. Ask for the waveform at 100%, 50% and 10%, and treat a datasheet that quotes only full output as untested. Our guide to dimming and switching in hotel lighting covers which protocols produce which behaviour.

On efficacy, the regulation sets a floor and nothing more. A product that just clears the threshold is compliant and still a poor choice for a 150-key hotel, because the operating cost sits with the owner for a decade. Use the legal limit as the entry ticket and the specification as the real requirement — our explanation of lumens and efficacy covers how to set that requirement.

5. Declarations and test reports

The Declaration of Conformity is a short document with a fixed job: identify the manufacturer, identify the product, list the directives and standards applied, name the signatory, and state that the product conforms. It is not a certificate, it is not issued by a third party for most luminaires, and it is worthless on its own.

What gives it weight is the test report set behind it. For a decorative luminaire the core is EN IEC 60598-1 with the relevant part 2 sheet for the family, EN 62471 for photobiological safety, EN 55015 and EN 61547 for emissions and immunity, EN 61000-3-2 for harmonics, and EN 61347 for the driver. Where IP is claimed, IEC 60529 applies; where a light source is supplied, the ecodesign information sheet applies.

Three checks catch most weak submissions. First, does the report name the exact model references being supplied, including the variant with the higher wattage or the different driver? Reports for a “similar” model are the most common gap. Second, is the laboratory accredited to ISO/IEC 17025 for the test in question? Third, does the report date precede the declaration, and does the declaration reference the standards that the report actually tested?

A fourth check is specific to projects: does the compliance file map certificates to product codes? A folder of PDFs with no index is not a compliance file. The schedule that ties each delivered fitting to a declaration is the document a clerk of works will actually use.

6. What to collect at handover

Handover is where compliance stops being a supplier’s problem and becomes the owner’s liability, and the collection should be assembled at tender and re-checked at delivery rather than started in the last week.

Handover document checklist for luminaire identification, declarations, reports and traceability
  • Declaration of Conformity per product family, EU and GB versions where both markets apply.
  • Test reports matching the standards named in each declaration, with model references that match the delivered goods.
  • RoHS declaration, including any exemption claimed by number, and a dated REACH SVHC statement with the SCIP reference where applicable.
  • Ecodesign product information sheet and energy label for every light source, with the EPREL registration number.
  • Driver datasheets, including dimming protocol, rated life and ambient temperature range.
  • Installation and maintenance instructions in the language of the market, and the label artwork as applied.

The most common reason a handover stalls is not a missing certificate. It is a certificate that cannot be tied to the fitting in the ceiling: a report for a 12 W version when 9 W was supplied, a driver substituted during production, or an energy label for a lamp that was changed at value engineering. The index solves this, and it takes an hour to build if it is built while the order is placed. Keep it in the O&M manual rather than in an email thread between the buyer and the supplier, because the person who needs it in year three will have access to neither the thread nor the buyer.

Preguntas frecuentes

Is UKCA still required for lighting in the UK?

For electrical safety and EMC, GB has continued to accept CE, with an indefinite extension confirmed in 2024. For GB RoHS and ecodesign, CE recognition was not extended the same way, so UKCA or the UK conformity route still applies. Dual marking with both declarations is the safe specification.

Does a CE mark cover RoHS?

RoHS is one of the directives behind the CE mark, so a compliant product declares it. But the mark itself does not prove it: the evidence is the RoHS declaration and the material test data behind it. Ask for the declaration, and check whether a brass component relies on a named exemption.

What is an EPREL number?

EPREL is the EU product database for energy labelling. Every light source placed on the EU market must be registered before it is sold, and the registration number links the product to its energy label and product information sheet. A supplier unable to give the number has not registered the product.

Are hotel luminaires covered by ERP 2019/2020?

Luminaires are covered indirectly. The regulation applies to light sources and separate control gear, so a luminaire must contain a compliant source and must allow replacement without destructive disassembly. Where the LED module is integrated and not replaceable, the luminaire is assessed as though the module were the source.

Siguiente paso

If you need the document set for a tender pack or a handover file, we can send the declarations, test reports and product information sheets for any fixture family under consideration, indexed by product code so the file can be checked against the delivery. Request the pack through compliance and sustainability, or send the schedule to our project enquiry desk and we will return the document list mapped to your specification lines. The finishes behind those declarations are covered in our guide to luminaire finishes and materials.

Christina

Hola, soy Christina, fundadora de Qilux Lighting.Qilux Lighting es un socio especializado en iluminación decorativa y comercial con sede en China, que trabaja con distribuidores, diseñadores de iluminación, integradores de sistemas y contratistas de proyectos de todo el mundo. Apoyamos proyectos comerciales y del sector hotelero mediante la traducción conceptos de diseño en soluciones de iluminación fiables y fabricables, conectando diseño, producción y entrega.

Última publicación

¿Tienes algún proyecto en mente?