Qilux Lighting

PRODUCTS / Mirror & Bathroom Lighting

Ayna ve Banyo Aydınlatması

0 fixtures match these filters.

Bu filtrelerle eşleşen armatür yok.

Başka bir tür, mekân veya malzeme deneyin ya da tüm koleksiyona göz atın.

Filtreleri sıfırla ↗

Farklı bir boyut veya yüzey mi gerekiyor?

Her model; ölçüler, malzemeler, yüzeyler ve ışık rengi proje gereksinimlerine göre uyarlanabilir.

Kişiye Özel Aydınlatmayı Keşfedin ↗

A bathroom is the only room in a hotel where the fitting is expected to survive steam, splashing and cleaning chemicals for a decade. That single constraint drives almost every decision below: the IP rating, the material, the finish, and where a fitting is allowed to sit.

How bathroom lighting differs by zone

IEC 60529 splits a bathroom into zones by distance from the water source, and each zone sets a minimum IP rating. Zone 0 sits inside the bath or shower tray and needs IPX7. Zone 1 covers the area directly above the bath up to 2.25 m and needs IPX4 as a minimum. Zone 2 extends 0.6 m beyond zone 1 and also needs IPX4. Outside zone 2 there is no legal minimum, but in a hotel we still specify IP44 for anything within reach of a shower head.

The practical consequence is that a decorative brass wall light can sit beside a basin but not inside the shower enclosure. Most failed specifications we see come from treating the whole room as one zone.

IP ratings that actually matter

IP44 protects against splashing water from any direction. IP65 protects against water jets. IPX7 survives temporary immersion. For bathroom lighting the useful set is small: IP44 for general wall lights and mirror lights, IP65 for anything mounted low or directly in the shower, IPX7 only for recessed fittings inside a tray.

The second digit matters more than the first in a bathroom. A fitting rated IPX4 with no dust protection is fine on a wall. A fitting rated IP6X but only IPX0 will fail within a year.

Mirror and vanity lighting

Mirror lighting is where bathroom lighting is actually judged. Light coming straight down from a ceiling downlight casts shadows under the eyes and nose, the most common complaint in hotel bathrooms. Light coming from both sides of the mirror at face height removes those shadows.

For a 1,200 mm mirror we specify two vertical lights at 1,600 to 1,700 mm above finished floor level, or a single backlit mirror where the diffuser runs the full perimeter. Backlit mirrors work well, but need 400 lux or more at the face to be usable for shaving or makeup.

Brass and stone in wet rooms

Unlacquered brass will patina in a bathroom. Some clients want that, most hotel operators do not. We specify lacquered brass or PVD-coated finishes for wet areas, and solid brass rather than brass-plated steel, because plating pits at the edges within two to three years.

Stone and marble shades are porous. In a bathroom they need sealing and should not sit in direct spray. Where a stone look is required we use a sealed stone composite, or place the fitting outside zone 1.

Specification checklist

Before a bathroom lighting schedule is signed off we check six things: a zone map for every room type, the IP rating of each fitting against that map, a CRI of at least 90 for mirror lights, one colour temperature across the room (2700 K or 3000 K, never mixed), dimming compatibility with the specified driver, and a cleaning regime that matches the finish.

Related reading